Skip to main content
background

PJ PYE PV200 S40 for detail work

Heat-weldable underlayer bituminous felt for detail work

Application:

  • Designed for roof detail work, including vertical detail work
  • Underlayer in multi-layer roof coverings, terraces and balconies
  • Waterproofing layer on ballasted roofs and under pavements intended for traffic
  • For concrete, sheet metal and wooden substrates, with or without thermal insulation
  • Waterproofing of underground parts of buildings
  • Effective vapor barrier layer

Properties:

  • Durable and puncture-resistant
  • Double SBS modification
  • For use in reduced ambient temperatures
  • Fixed by welding and mechanically
  • Easy and convenient for roof detail work
  • Ensures quick and easy installation at the vertical/horizontal junction of any roof element (chimneys, parapets, ventilation pipes, etc.)
  • Recommended for installing starter strips on the roof
  • Convenient to use on foundations

Available packaging:

  • 0,5 x 7,5 m

Type of reinforcement

non-woven polyester reinforced with glass fibers

Top finishing

fine-grained

Low temperature flexibility

≤ -20°C

Width

0,5 m

Thickness

4,0 mm ± 10%

Resistance to external fire exposure*
*applies to the examined layer systems

Broof(t1), Broof(t2)

Reaction to fire

class E

Watertightness:
waterproof at a pressure

≥ 2 kPa (method A) 
≥ 10 kPa (method A) 
≥ 60 kPa (method B) 
≥ 250 kPa (method B)

Durability:
- durability after artificial ageing, watertightness
- durability against chemical
- after artificial ageing, vapour diffusion
- chemicals resistance


≥ 60 kPa (method B)
acc. to annex A of standard EN 13969
3,47E+11 m²·Pa·s/kg ± 50% 
acc. to annex A of standard EN 13970

Maximum tensile force:
- longitudinal
  extension
- transversal
  extension


700 +300, -200 N/50 mm 
(50 ± 20) % 
500 +300, -200 N/50 mm 
(50 ± 20) %

Resistance of the joint:
- shear strength
• longitudinal joint
• transversal joint



500 +300, -200 N/50 mm 
700 +300, -200 N/50 mm

Resistance to root penetration

NPD

Resistance to tearing:
- longitudinal
- transversal


300 ± 200 N 
300 ± 200 N

Resistance to static loading

≥ 10 kg (method B)

Resistance to impact

≥ 700 mm (method A)

Dimensional stability

≤ 0,5%

Permeation of water vapour

3,47E+11 m²·Pa·s/kg ± 25%

Diffusion resistance coefficient Sd

approx. 70 m

Reference document(s)

EN 13707:2004+A2:2009; 
EN 13969:2004; 
EN 13969:2004/A1:2006; 
EN 13970:2004; 
EN 13970:2004/A1:2006

  • Making an insulation using NEXLER PJ PYE PV200 S40 for detail work bituminous felt should be carried out according to the technical design, in accordance with the current building regulations and the detailed guidelines for the design and execution of insulation contained in NEXLER Insulation Systems and the Technical Data Sheet.
    The bituminous felt should be installed in ambient temperatures of above 0°C, this requirement applies to the time of day and night.
    Do not carry out insulation work during strong winds and precipitation.

Get more details

No image available

NEXLER Flashing Felts: Fast, Effective Insulation for Roof Flashings

Insulating vertical roof elements—such as chimneys, parapets, and circular roof penetrations—are among the most time-consuming and challenging tasks for any roofer.

See also

BITFLEX Primer 8 kg 320x320

BITFLEX Primer

Quick-drying bituminous and anionic primer (concentrate)

Find out more SYSTEM
Papy specjalne - Premium pye pv250 s53h po 320x320

PREMIUM PYE PV250 S53H for detail work

Heat-weldable top layer bituminous felt for detail work

Find out more SIMILAR
Papy specjalne - Stick po 320x320

Stick for detail work

Self-adhesive underlayer bituminous felt for detail work

Find out more SIMILAR
Search for a document

Archival documents

Type of document
Year
Month