Skip to main content
background

Renovation Base

Heat-weldable underlayer bituminous felt

Application:

  • Underlayer bituminous felt for ventilation of damp roofs

Properties:

  • With a system of small channels to ventilate damp roofs
  • Double SBS modification
  • For use in reduced ambient temperatures

Available packaging:

  • 10 m

Type of reinforcement

non-woven polyester reinforced with glass fibers

Low temperature flexibility

≤ -20°C

Width

≥ 0,99 m

Straightforwardness

≤ 20 mm per 10 m roll length

Resistance to external fire exposure*
*applies to the examined layer systems

Broof(t1), Broof(t2), Broof(t3)

Reaction to fire

class E

Watertightness:
waterproof at a pressure


≥ 10 kPa (method A)

Maximum tensile force:
- longitudinal
  extension
- transversal
  extension


800 ± 200 N/50 mm
(50 ± 25) %
600 ± 200 N/50 mm
(50 ± 25) %

Dimensional stability

≤ 0,5%

Resistance of the joint :
- shear strength 
  • longitudinal joint 
  • transversal joint
- tear off strength
  • longitudinal joint
  • transversal joint



450 ± 250 N/50 mm
600 ± 200 N/50 mm

Resistance to impact

≥ 1000 mm (method A)

Resistance to root penetration

NPD

Reference document(s)

EN 13707:2004+A2:2009

  • Making an insulation using NEXLER Renovation Base bituminous felt should be carried out according to the technical design, in accordance with the current building regulations and the detailed guidelines for the design and execution of insulation contained in NEXLER Insulation Systems and the Technical Data Sheet.
    The bituminous felt should be installed in ambient temperatures of above 0°C, this requirement applies to the time of day and night.
    Do not carry out insulation work during strong winds and precipitation.

See also

BITFLEX Primer 8 kg 320x320

BITFLEX Primer

Quick-drying bituminous and anionic primer (concentrate)

Find out more SYSTEM
Bitumy rozpuszczalnikowe - Penetrator g7 320x320

Penetrator G7

Quick-drying primer modified with SBS for under bituminous felt

Find out more SYSTEM
null

Renovation

Weldable ventilation top bituminous felt

Find out more SIMILAR

Documents for download

icon Declaration of Performance

icon Technical Data Sheet

Search for a document

Archival documents

Type of document
Year
Month