PREMIUM PYE PV 30

Heat-weldable underlayer bituminous felt

Application:

  • Underlayer in multi-layer roof coverings, terraces and balconies
  • Damp-proofing and waterproofing of underground building structures

Properties:

  • It has a strong and durable reinforcement
  • Fixed by welding and mechanically
  • Double SBS modification
  • Compliance with TL2 requirements

Type of reinforcement

non-woven polyester reinforced with glass fibers

Top finishing

fine-grained

Low temperature flexibility

≤ -25°C

Width

≥ 0,99 m

Straightforwardness

≤ 20 mm per 10 m roll length

Basis weight

3,0 kg/m2 ± 5%

Resistance to external fire exposure*
*applies to the examined layer systems

Broof(t1), Broof(t2), Broof(t3)

Reaction to fire

class E

Watertightness:
waterproof at a pressure


≥ 10 kPa (method A)
≥ 60 kPa (method B)
≥ 300 kPa (method B)

Maximum tensile force:
- longitudinal
  extension
- transversal
  extension


800 ± 200 N/50 mm
(50 ± 25) %
600 ± 200 N/50 mm
(50 ± 25) %

Resistance to root penetration

NPD

Resistance to static loading

≥ 5 kg (method B)

Resistance to impact

≥ 600 mm (method A)

Resistance to tearing:
- longitudinal
- transversal


300 ± 100 N
400 ± 100 N

Dimensional stability

≤ 0,6%

Durability:
- durability after artificial ageing, watertightness
- durability against chemical


≥ 60 kPa (method B)
acc. to annex A of standard EN 13969

Durability: flow resistance at elevated temperature

≥ 100°C

Reference document(s)

EN 13707:2004+A2:2009; 
EN 13969:2004;
EN 13969:2004/A1:2006

  • Making an insulation using NEXLER PREMIUM PYE PV 30 bituminous felt should be carried out according to the technical design, in accordance with the current building regulations and the detailed guidelines for the design and execution of insulation contained in NEXLER Insulation Systems and the Technical Data Sheet.
    The bituminous felt should be installed in ambient temperatures of above 0°C, this requirement applies to the time of day and night.
    Do not carry out insulation work during strong winds and precipitation.

See also

BITFLEX Primer 8 kg 320x320

BITFLEX Primer

Quick-drying bituminous and anionic primer (concentrate)

Find out more SYSTEM
Bitumy rozpuszczalnikowe - Penetrator g7 320x320

Penetrator G7

Quick-drying primer modified with SBS for under bituminous felt

Find out more SYSTEM
papa_podkładowa_320x320

PREMIUM PYE PV 40

Heat-weldable underlayer bituminous felt

Find out more SIMILAR

Documents for download

icon Declaration of Performance

icon Technical Data Sheet

Search for a document

Archival documents

Type of document
Year
Month