Skip to main content
background

PREMIUM PYE PV160 S30

Heat-weldable underlayer bituminous felt

Application:

  • Underlayer in multi-layer roof coverings, terraces and balconies, for any type of substrate
  • Waterproofing layer on ballasted roofs and under pavements intended for traffic
  • Waterproofing of underground parts of buildings
  • Effective vapor barrier layer

Properties:

  • Durable and puncture-resistant
  • Double SBS modification
  • For use in reduced ambient temperatures
  • Fixed by welding and mechanically

Available packaging:

  • 7,5 m

Type of reinforcement

non-woven polyester

Top finishing

fine-grained

Low temperature flexibility

≤ -15°C

Width

≥ 0,99 m

Straightforwardness

≤ 15 mm per 7,5 m roll length

Thickness

(3,0 ± 0,2) mm

Resistance to external fire exposure*
*applies to the examined layer systems

Broof(t1)

Reaction to fire

class E

Watertightness:
waterproof at a pressure

≥ 2 kPa (method A)
≥ 10 kPa (method A)
≥ 60 kPa (method B)

Durability:
- durability after artificial ageing, watertightness
- durability against chemical
- after artificial ageing, vapour diffusion
- chemicals resistance

≥ 60 kPa (metoda B), ≥ 2 kPa (metoda A)
acc. to annex A of standard EN 13969
7,8E+11 m²·Pa·s/kg ± 50%
acc. to annex A of standard EN 13970

Maximum tensile force:
- longitudinal
  extension
- transversal
  extension


750 ± 150 N/50 mm
(45 ± 15) %
500 ± 150 N/50 mm
(45 ± 15) %

Resistance of the joint:
- shear strength
• longitudinal joint
• transversal joint



650 ± 250 N/50 mm
900 ± 250 N/50 mm

Resistance to root penetration

NPD

Resistance to tearing:
- longitudinal
- transversal


250 ± 100 N
250 ± 100 N

Resistance to static loading

≥ 10 kg (method B)

Resistance to impact

≥ 1000 mm (method A)

Dimensional stability

≤ 1%

Permeation of water vapour

7,8E+11 m²·Pa·s/kg ± 25%

Diffusion resistance coefficient Sd

approx. 156 m

Reference document(s)

EN 13707:2004+A2:2009;
EN 13969:2004;
EN 13969:2004/A1:2007;
EN 13970:2004;
EN 13970:2004/A1:2006

  • Making an insulation using NEXLER PREMIUM PYE PV160 S30 bituminous felt should be carried out according to the technical design, in accordance with the current building regulations and the detailed guidelines for the design and execution of insulation contained in NEXLER Insulation Systems and the Technical Data Sheet.
    The bituminous felt should be installed in ambient temperatures of above 0°C, this requirement applies to the time of day and night.
    Do not carry out insulation work during strong winds and precipitation.

See also

BITFLEX Primer 8 kg 320x320

BITFLEX Primer

Quick-drying bituminous and anionic primer (concentrate)

Find out more SYSTEM
Bitumy rozpuszczalnikowe - Penetrator g7 320x320

Penetrator G7

Quick-drying primer modified with SBS for under bituminous felt

Find out more SYSTEM
papa_podkładowa_320x320

PREMIUM PYE PV180 S40

Heat-weldable underlayer bituminous felt

Find out more SIMILAR
papa_podkładowa_320x320

PJ PYE PV200 S40

Heat-weldable underlayer bituminous felt

Find out more SIMILAR

Documents for download

icon Declaration of Performance

Search for a document

Archival documents

Type of document
Year
Month