Skip to main content
background

Parking+

Heat-weldable bituminous felt

Application:

  • Single-layer waterproofing of concrete surfaces intended for vehicle traffic such as parking lots, garages etc.
  • For roofs, terraces and balconies as waterproofing

Properties:

  • Double SBS modification
  • Durable and puncture-resistant
  • For use in reduced ambient temperatures
  • Flexible in a wide temperature range
  • Approved for use under heavy surface protection
  • Fixed by welding

Available packaging:

  • 10 m

Type of reinforcement

non-woven polyester

Top finishing

coarse grained

Low temperature flexibility

≤ -20°C

Width

0,99 m

Thickness

(5,5 ± 0,5) mm

Reaction to fire

class E

Watertightness:
waterproof at a pressure


≥ 10 kPa (method A)

Watertightness: water absorption

≤ 0,3%

Maximum tensile force:
- longitudinal
  extension
- transversal
  extension


1250 ± 150 N/50 mm
(55 ± 15) %
950 ± 150 N/50 mm
(60 ± 15) %

Reference document(s)

EN 14695:2010;
EN 13707:2004+A2:2009

Resistance to root penetration

NPD

Resistance to static loading

≥ 20 kg (method B)

Resistance to impact

≥ 1750 mm (method A)

Bond strength

≥ 0,5 N/mm²

Resistance to shear

≥ 0,2 N/mm²

Compatibility

≥ 100%

Crack bridging ability:
- substrate crack sealing ability
- specification conformity at temp.


type 3
≤ -10°C

Resistance to heat impact

≤ 0,8 mm

Resistance to perforation (compaction)

requirements met (method 2)

Durability:
- water absorption
- thermal ageing behavior as follows:
 flexibility at low temperature
 flow resistance at elevated temperature
- compatibility by heat conditioning


≤ 0,3%

≤ -10°C
(100 ± 10)°C
≥ 100%

Performance while cold-bending

≤ -20°C

Durability: flow resistance at elevated temperature

(100 ± 10)°C

Dimensional stability

≤ 0,5%
  • Making an insulation using NEXLER Parking+ bituminous felt should be carried out according to the technical design, in accordance with the current building regulations and the detailed guidelines for the design and execution of insulation contained in NEXLER Insulation Systems and the Technical Data Sheet.
    The bituminous felt should be installed in ambient temperatures of above +5°C, this requirement applies to the time of day and night.
    Do not carry out insulation work during strong winds and precipitation.

See also

NEXLER EPOLIS EP 601_EN_320px

EPOLIS EP 601

Two-component epoxy primer

Find out more SYSTEM
Bitumy rozpuszczalnikowe - Penetrator g7 320x320

Penetrator G7

Quick-drying primer modified with SBS for under bituminous felt

Find out more SYSTEM
Papy specjalne - Most 320x320

Most+

Heat-weldable bituminous felt

Find out more SIMILAR

Documents for download

icon Declaration of Performance

icon Technical Data Sheet

Search for a document

Archival documents

Type of document
Year
Month