Skip to main content
background

Alu S35

Heat weldable underlayer bituminous felt

Application:

  • Vapour barrier for roofs and terraces under the thermal insulation layer
  • Horizontal damp-proof insulation
  • Radon barrier in underground parts of buildings under floors

Properties:

  • Excellent vapour barrier properties
  • Effective protection against radon radiation
  • Fixed by welding
  • Composite reinforcement made of aluminium

Available packaging:

  • 10 m

Type of reinforcement

composite of aluminum film and glass veil

Top finishing

fine-grained

Low temperature flexibility

≤ 0°C

Width

≥ 1 m

Straightforwardness

≤ 20 mm per 10 m roll length

Thickness

3,5 mm ± 0,2 mm

Resistance to external fire exposure*
*applies to the examined layer systems

Broof(t1)

Reaction to fire

class E

Watertightness:
waterproof at a pressure


≥ 2 kPa (method A)
≥ 10 kPa (method B)

Maximum tensile force:
- longitudinal
  extension
- transversal
  extension


500 ± 200 N/50 mm
(4 ± 2) %
300 ± 150 N/50 mm
(4 ± 2) %

Resistance to root penetration

NPD

Resistance to static loading

≥ 5 kg (method B)

Resistance to impact

≥ 600 mm (method A)

Resistance to tearing:
- longitudinal
- transversal


150 ± 100 N
150 ± 100 N

Resistance of the joint:
- shear strength
• longitudinal joint
• transversal joint



300 ± 150 N/50 mm
500 ± 200 N/50 mm

Permeation of water vapour

1,3E+12 m²·Pa·s/kg ± 25%

Diffusion resistance coefficient Sd

approx. 260 m

Radon diffusion coefficient

D < 10⁻¹⁴ m²/s

Durability:
- durability after artificial ageing, watertightness
- durability against chemical
- after artificial ageing, vapour diffusion
- chemicals resistance


≥ 2 kPa (method A)
acc. to annex A of standard EN 13969
1,3E+12 m²·Pa·s/kg ± 50%
acc. to annex A of standard EN 13970

Reference document(s)

EN 13707:2004+A2:2009;
EN 13969:2004; EN 13969:2004/A1:2007;
EN 13970:2004; EN 13970:2004/A1:2006

  • Making an insulation using NEXLER Alu S35 bituminous felt should be carried out according to the technical design, in accordance with the current building regulations and the detailed guidelines for the design and execution of insulation contained in NEXLER Insulation Systems and the Technical Data Sheet.
    The bituminous felt should be installed in ambient temperatures of above +5°C, this requirement applies to the time of day and night.
    Do not carry out insulation work during strong winds and precipitation.

See also

Bitumy rozpuszczalnikowe - Penetrator g7 320x320

Penetrator G7

Quick-drying primer modified with SBS for under bituminous felt

Find out more SYSTEM
BITFLEX Primer 8 kg 320x320

BITFLEX Primer

Quick-drying bituminous and anionic primer (concentrate)

Find out more SYSTEM
Papy specjalne - Alu s40 320x320

Alu S40

Heat weldable underlayer bituminous felt

Find out more SIMILAR

Documents for download

icon Declaration of Performance

icon Technical Data Sheet

Search for a document

Archival documents

Type of document
Year
Month